FPI I2450M Manual page 29

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 1
TEST RESULTS - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
I2450
Run #:
1
Average Gas Velocity in Dilution Tunnel (ft/sec)
Average Gas Flow Rate in Dilution Tunnel (dscf/hr)
Particulate Concentration, dry-standard (g/dscf)
Difference from Average Total Particulate Emissions (g)
Difference from Average Emissions Factor (g/kg)
Quality Checks
Dual Train Precision
Filter Temps
Face Velocity
Leakage Rate
Ambient Temp
Negative Probe Weight Evaluation
Pro-Rate Variation
PFS-TECO
Burn Rate (kg/hr):
Total Sample Volume (ft
Average Gas Meter Temperature (°F)
Total Sample Volume (dscf)
Average Tunnel Temperature (°F)
Total Time of Test (min)
Total Particulate Catch (mg)
Total PM Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
Final Average Results
Total Particulate Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
HHV Efficiency (%)
LHV Efficiency (%)
CO Emissions (g/min)
Requirement
Each train within 7.5% of average emissions (in
grams), or emission factors within 0.5 g/kg
>80 °F, <90 °F
< 30 ft/min
Less than 4% of average sample rate
55-90 °F
<5% of Total Catch
90% of readings between 90-110%; none greater
than 120% or less than 80%
Page 2 of 23
Job #:
Tracking #:
Technician:
Date:
2.74
Ambient
Sample
Sample
Train A
3
)
22.014
28.746
81.2
89.3
21.405
27.830
0.1
9.7
0.0000047
0.0003485
0.16
11.78
0.05
3.72
-
1.28
-
0.45
-
0.05
11.32
3.58
1.23
66.0%
70.6%
1.58
Observed
See Above
Min: 84 / Max: 89
8.5
0.002 cfm
Min: 77 / Max: 84
Probe Catch Not
Negative
See Data Tabs
19-469
0025
ADK/SJB
4/8/2019
Sample
1st Hour
Train B
Filter
28.203
8.920
17.66
10813.7
99.6
86.5
26.690
8.678
135.6
190
8.6
4.3
0.0003222
0.0004955
10.87
5.31
3.43
5.31
1.18
-
-
0.45
-
0.05
Result
OK
OK
OK
OK
OK
OK
CHECK 10 MIN. INTERVAL
PRO-RATES

Advertisement

Table of Contents