Model: I2450
Test Notes
Test Burn Start Time:
Air Control Setting:
Time
0:00
Started with 1.7 lbs kindling and torch for 20 sec, door cracked
1:55
Door Closed
6:00
Added 2.7 lb of kindling & startup
21:20
Added remaining 2.6 lbs of start-up fuel
26:00
Leveled remaining coal bed, zeroed scale, loaded test fuel
46:00
Fan on high
60:00
Changed filter A
175:00
Changed filter B
190:00
Test end @ 2.1 lb
Test Burn End Time:
Calibration Gas Values:
Calibration Results:
Zero
Time
09:10
CO
0.00
2
CO
0.0000
Flue Gas Probe Leak Check:
Technician Signature:
ASTM E3053 Wood Heater Run Sheets
Job Number: 19-469
Run Number: 1
Wood Heater Run Notes
11:50
Fully Open
15:00
Flue Gas Concentration Measurement
Span Gas
Mid Gas
Pre Test
Mid
09:14
10.04
2.480
Initial: No Leakage
Notes
CO
(%): 16.93
CO (%): 4.330
2
CO
(%): 10.00
CO (%): 2.51
2
Span
Zero
09:12
15:17
16.93
0.12
4.330
-0.011
Final: No Leakage
Date:
Tracking #: 0025
Test Date: 4/8/2019
Post Test
Mid
Span
15:15
15:20
9.72
16.49
2.444
4.289
4/8/2019
Page 1 of 3