Run 1
Client:
FPI
Model:
I2450
Run #:
1
TRAIN A (1st Hour)
Sample Component
A. Front filter catch
B. Rear filter catch
C. Probe catch*
D. O-Ring catch*
TRAIN A (Post 1st hour)
Sample Component
A. Front filter catch
B. Rear filter catch
C. Probe catch*
D. O-Ring catch*
TRAIN B
Sample Component
A. Front filter catch
B. Rear filter catch
C. Probe catch*
D. O-Ring catch*
AMBIENT
Sample Component
A. Filter catch*
*Particulate catch that results in a negative number, is assumed to be zero for probes and O-rings, negative numbers for
filters are assumed to be part of the O-Ring weight.
PFS-TECO
LAB SAMPLE DATA - ASTM E2515
Filter, Probe, or
Sample Type
Filter
Filter
Probe
O-Ring
Filter, Probe, or
Sample Type
Filter
Filter
Probe
O-Ring
Train A Aggregate Total Particulate, mg:
Filter, Probe, or
Reagent
Filter
Filter
Probe
O-Ring
Filter, Probe, or
Reagent
Filter
Job #:
Tracking #:
Technician:
Date:
O-Ring #
Final, mg
T129
92.9
Sub-Total
Total Particulate, mg:
O-Ring #
Final, mg
T130
183.3
T131
14A
116817.0
14A
3360.6
Sub-Total
Total Particulate, mg:
O-Ring #
Final, mg
T132/T135
272.0
T133
14B
116770.8
14B
3334.9
Total Particulate, mg:
O-Ring #
Final, mg
T134
86.8
Total Particulate, mg:
Page 23 of 23
19-469
0025
ADK/SJB
4/8/2019
Weights
Tare, mg
Particulate, mg
88.6
4.3
0.0
0.0
0.0
4.3
Weights
Tare, mg
Particulate, mg
89.6
4.8
88.9
116816.8
0.2
3360.2
0.4
5.4
9.7
Weights
Tare, mg
Particulate, mg
176.1
8.3
87.6
116770.8
0.0
3334.6
0.3
8.6
Weights
Tare, mg
Particulate, mg
86.7
0.1
0.1