FPI I2450M Manual page 111

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 3.xlsm
TEST RESULTS - ASTM E3053 / ASTM E2515
Client:
FPI
Model:
I2450
Run #:
3
Incomplete Test Run - Results could not be computed
Difference from Average Total Particulate Emissions (g)
Quality Checks
Dual Train Precision
Filter Temps
Face Velocity
Leakage Rate
Ambient Temp
Negative Probe Weight Evaluation
Pro-Rate Variation
PFS-TECO
Total Sample Volume (ft
Average Gas Velocity in Dilution Tunnel (ft/sec)
Average Gas Flow Rate in Dilution Tunnel (dscf/hr)
Average Gas Meter Temperature (°F)
Total Sample Volume (dscf)
Average Tunnel Temperature (°F)
Total Time of Test (min)
Total Particulate Catch (mg)
Particulate Concentration, dry-standard (g/dscf)
Total PM Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
Difference from Average Emissions Factor (g/kg)
Final Average Results
Total Particulate Emissions (g)
Particulate Emission Rate (g/hr)
Emissions Factor (g/kg)
CO Emissions (g/min)
Each train within 7.5% of average emissions (in
grams), or emission factors within 0.5 g/kg
Less than 4% of average sample rate
90% of readings between 90-110%; none greater
than 120% or less than 80%
Burn Rate (kg/hr):
6.31
Ambient
Sample
3
)
0.000
81.1
0.000
-86.5
0.0000000
0.00
0.00
HHV Efficiency (%)
LHV Efficiency (%)
Requirement
>80 °F, <90 °F
< 30 ft/min
55-90 °F
<5% of Total Catch
Page 2 of 19
Job #:
19-469
Tracking #:
0025
Technician:
ADK/SJB
Date:
4/10/2019
Sample
Sample
Train A
Train B
12.568
12.591
87.8
94.2
12.421
12.206
-260.1
-173.9
-0.0209400
-0.0142476 -0.0100784
-339.55
-231.03
-226.37
-154.02
-
-35.77
-24.34
-
54.26
54.26
-
5.72
5.72
-285.29
-190.19
-30.06
63.7%
68.2%
5.37
Observed
Result
Not Acceptable
See Above
OK
Min: 84 / Max: 87
OK
8.7
0.002 cfm
OK
OK
Min: 80 / Max: 82
Probe Catch Not
OK
Negative
CHECK 10 MIN. INTERVAL
See Data Tabs
PRO-RATES
1st Hour
Filter
8.743
16.89
10810.3
86.9
8.642
119.4
90
-87.1
-108.95
-108.95
-
-
-