FPI I2450M Manual page 132

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 4
Heat Transfer Efficiency
Test Load Weight (dry kg)
VERSION:
PFS-TECO
B415.1 Efficiency Results
Manufacturer:
Model:
Date:
Run:
Control #:
Test Duration:
Output Category:
Test Results in Accordance with CSA B415.1-09
Overall Efficiency
Combustion Efficiency
Output Rate (kJ/h)
Burn Rate (kg/h)
Input (kJ/h)
MC wet (%)
MC dry (%)
Particulate (g )
CO (g)
Test Duration (h)
Emissions
g/MJ Output
g/kg Dry Fuel
g/h
g/min
lb/MM Btu Output
Air/Fuel Ratio (A/F)
2.2
FPI
I2450
04/11/19
4
19-469
471
Medium
HHV Basis
66.4%
95.9%
69.2%
16,410
1.24
24,708
9.72
18.25
22.33
6.97
638
7.85
Particulate
0.05
0.72
0.89
0.01
0.13
24.98
12/14/2009
Page 3 of 50
LHV Basis
71.0%
95.9%
74.0%
15,567
(Btu/h)
2.73
(lb/h)
23,439
(Btu/h)
21.42
dry lb
CO
4.95
65.66
81.28
1.35
11.51

Advertisement

Table of Contents
loading

Table of Contents