Zero clearance direct vent gas fireplace (72 pages)
Summary of Contents for FPI FP90
Page 1
Owners & FP90 Wood Fireplace Installation Manual US Edition Regency High Effi ciency EPA Certifi ed Fireplace MODEL: FP90 www.regency-fi re.com Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference.
Page 2
States. This means that it meets the strictest standards in providing you with the latest in clean burning technology and effi ciency. Specifi cations may vary widely. Consult with your FPI Dealer for local considerations. Keep those REGENCY FIRES burning. FPI FP90 Wood Fireplace...
SAFETY LABEL This is a copy of the label that accompanies each Regency Fireplace. It is located inside the lower louver opening on the left side. We have printed a copy of the contents here for your review. NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
16) DO NOT use a fi replace insert or any other product not specifi ed by Regency for use with this fi replace. 17) NEVER, under any circumstances, install a fi replace, chimney component or any...
(92mm) 4-3/4" (121mm) INSTALLATION The FP90 main unit consists of the following: 1) The main fi re box and heat exchanger 2) Double doors with ceramic glass 3) Vermiculite side panels and baffl e 4) The insulated outside air duct 5) Hearth Safety Strip 6) 1"...
INSTALLATION CLEARANCES AND HEIGHT REQUIREMENTS The FP90 may be placed on or near construction materials. The combustion air kit, fi re stop spacer and roof fl ashings (not chase fl ashings) may be placed directly on or against normal construction materials.
Nailing Strips. The Nailing Strips can also be moved forward and back by adjusting the screws that mount them to the fi replace. FPI FP90 Wood Fireplace FIREPLACE ENCLOSURE FRAMING As per the diagram, the framing of the main enclosure should not infringe on the area above the fi...
fl oor beneath the hearth extension. Note: The “Z” type safety strip is not supplied by Regency and must be fabricated locally. FINISHING MATERIAL FINISHING MATERIAL NON-COMBUSTIBLE NON-COMBUSTIBLE 1/2"(13mm) THICK...
CHIMNEY SYSTEM CONSIDERATIONS Regency’s FP90 Fireplace is to be installed with one of the following Chimney Systems only. Chimney systems only 8" (203mm) diameter are to be used. In U.S.A. Any of the following air-cooled chimney systems may be used:...
1) Install stand-offs and insulation strip to the unit. 2) Complete framing and installation of the nailing strips for the FP90. I M P O R TA N T: R e m o v e g o l d accessories such as louvers while installing to avoid marking.
This may cause a negative pressure in the house allowing smoke to back into the home. FPI FP90 Wood Fireplace TABLE 1 Required Firestop, Radiation Shield, Or...
GRAVITY AIR FEED KIT OPTION The Gravity Air Feed Kit is designed to extend the heat output vent above the FP90 to the front or the side. The upper louver opening is blocked off and fl ex vent is connected to the vent holes in the top of the unit and run to discharge vent grilles.
Use the chase vent supplied with the FP90 unit only or any equivalent one with the same or less restriction of air fl ow. 12) Recheck all fl ex vent-work connections to make sure that they are secure.
Attach arch edge and bottom of grill edge to unit. The door arch fl oats at each end so that it can be adjusted to match the curve of the door. Metal Filler Strips RIGHT SIDE FPI FP90 Wood Fireplace...
Face Header. Example 1: Face of Fireplace Flush with Wall Framing. Top View Example 2: Face of Fireplace Flush with Non-Combustible. Top View FPI FP90 Wood Fireplace 60" (1524mm) 2-1/2" (64mm) Metal Filler Strip 29" (637mm) 48"...
The air tube will be diffi cult to snap into place because it has to be a snug fi t in order to prevent it from falling out when a fi re is burning. FPI FP90 Wood Fireplace...
5) The fi rebricks are brittle and can be damaged if the plug is replaced carelessly or pieces that are too large are forced through the hole. FPI FP90 Wood Fireplace Ash Drawer Kit Installation 1) Remove the bricks from the fl oor of the fi rebox.
6) Slide the fan transfer tray back into the unit and hook up wires to the Control Box and mount the thermo disc in place. FAN INSTALLATION Diagram 1 910-903 910-516 GROUND NEUTRAL - FROM FAN 910-896 VARIABLE SWITCH 910-330 Diagram 2 POWER CORD 910-519 GROUND FPI FP90 Wood Fireplace...
NOTE: ONCE THE TEMPLATE IS MOUNTED CHECK TO MAKE SURE THE SIDES ARE PLUMB AND 43" (1092mm) IN WIDTH FPI FP90 Wood Fireplace THE TOP IS ANGLED BACK AT 5 DEGREES TO ENSURE THAT THE TEMPLATE FITS TIGHT TO THE UNIT.
Page 24
TO PREVENT MASONRY FACING MATERIAL FROM HITTING THE TOP STIFFENER LOCATED ON THE BACK OF THE SURROUND WHICH IS HIGHER THAN THIS EDGE. INSTALL THE SURROUND TEMPLATE ONTO THE UNIT WITH THE SAME MOUNTING SCREWS AS THE SURROUND. FPI FP90 Wood Fireplace...
½” (13 mm) from the face of the unit. This will allow for the wall sheathing to be fl ush with the face of the unit and allow the trim to be installed correctly (refer to Diagram 1). FPI FP90 Wood Fireplace INSTALLATION Front Trim...
Page 26
fi nish from cracking. STANDOFF 11.000" (279mm) NON-COMBUSTIBLE (i.e. Cement Board) 2x4 FRAMING DRYWALL FINISH COAT INSTALL TRIM ON NAILING STRIP THEN TUCK NON-COMBUSTIBLE SHEATHING INTO POCKET TO CONCEAL EDGE. Diagram 2 FPI FP90 Wood Fireplace...
2) Fasten the handles to the screen using the fasteners provided. FPI FP90 Wood Fireplace INSTALLATION INSTALLING THE SCREEN ON THE FIREPLACE 1) Ensure doors are opened enough to allow fi re screen to be installed.
3) Close the bottom louver and secure on the magnets provided (refer to Diagrams 1 and 2). Bottom Louver Rotation Pin Tab (x2) Diagram 1 Top Louver Mounting Tab (x2) Diagram 2 Bottom Louver Mounting Sequence FPI FP90 Wood Fireplace...
(#8 x ½”). Optional: 4) Install the optional masonry cover plate to the facing guides with four (4) screws (¼-20 x ½”). FPI FP90 Wood Fireplace INSTALLATION Installing the Excalibur Faceplate 1) Remove the left and right door from the fi replace.
Remove the 2 studs on the sides of the Hood. Insert the new studs through the holes and secure them by fi rst putting on the washer and then tighten the nut. Re-install faceplate with plated screws. FPI FP90 Wood Fireplace...
fi re at a moderate level. FPI FP90 Wood Fireplace OPERATING INSTRUCTIONS WARNING: Never build a roaring fi re in a cold stove. Always warm your stove...
5/8" (16mm) diameter oval, medium density material, 34" (864mm) long for each side. A proper high temperature gasket adhesive is required. Contact your dealer for the Regency Gasket Repair Kit. DOOR HINGES Grease door hinges with high temperature grease regularly for smooth operation and to avoid squeaks.
The authorized selling dealer is responsible for all in-fi eld service work carried out on your Regency product. FPI will not be liable for results or costs of workmanship from unauthorized service persons or dealers.