FPI I2450M Manual page 213

Wood-fired fireplace insert
Table of Contents

Advertisement

Run 2
M
– Weight of test fuel load, dry basis, lb (kg)
Fldb
ASTM E3053 equation (1)
M
= Σ((M
Fldb
FLnwb
Where,
M
=
Weight of each test fuel piece, n, in test fuel load per 8.4.1, wet basis, lb (kg)
FLnwb
MC
=
Average fuel moisture of test fuel piece, n, in test fuel load, % dry basis
FLn
n
=
individual test fuel pieces that comprise the test fuel load, as applicable.
Sample Calculation:
n
M
FLnwb
1
4.10
2
6.19
3
4.23
4
7.98
5
3.31
6
0.00
7
0.00
M
=
21.24
Fldb
M
=
9.63
Fldb
PFS-TECO
)(100/(100 + MC
)))
FLn
MC
(M
FLn
18.7
4.1 (100) / ( 100+ 18.7 )) =
24.2
6.19 (100) / ( 100+ 24.2 )) =
21.6
4.23 (100) / ( 100+ 21.6 )) =
21.8
7.98 (100) / ( 100+ 21.8 )) =
19.5
3.31 (100) / ( 100+ 19.5 )) =
NA
lbs
kg
)(100/(100 + MC
))
FLnwb
FLn
3.45
4.98
3.48
6.55
2.77
N/A
N/A
SUM
21.24
Page 2 of 17
-
-