Identification Commands; Initialization Commands - TDK-Lambda GH10-100 User Manual

Table of Contents

Advertisement

4.10.4

Identification Commands

IDN?
Query
Returns
Example
REV?
Query
Returns
Example
SN?
Query
Returns
Example
DATE?
Query
Returns
Example
4.10.5

Initialization Commands

CLS
Function
Returns
ADR <NR1>
Function
Returns
RMT <DSC>
Function
Parameters
Query
Returns
Returns the power supply model identification as an ASCII string (one comma,
no spaces)
<SRD>
TDK-LAMBDA,G100-50
Returns the software version as an ASCII string
<SRD>
G:XX.XXX
Returns the supply's serial number. Up to 12 characters in any format
<SRD>
111111-22222
Returns the date of last calibration. Format: yyyy/mm/dd
<SRD>
2017/12/17
Clear Status. Sets FEVE and SEVE registers to zeroes
<DSC> OK
Send 'ADR' and address (0 to 31) to open a communication channel.
<DSC> OK
Set the power supply control source (front panel or communication) to local,
remote or LLO mode.
Local – Enable front panel control.
Remote – Disable front panel settings change (settings preview only).
LLO – same as Remote + Disable front panel unlock function by front panel.
Change mode by communication or AC recycle.
0|1|2 or LOC|REM|LLO
RMT?
<DSC> LOC|REM|LLO
85