RCL <NR1>
Function
Parameters
MODE?
Query
Return
MS?
Query
Return
Power supply does not execute commands in the Slave mode.
4.10.7

Global Output Commands

General
Global commands are received by all Power Supplies connected to the BUS, without any need of
individual addressing commands.
All Power Supplies execute commands immediately. There is no acknowledgment back to the PC.
A delay of at-least 10mSec must be set after each global command. Error messages are not
reported back to the issuing PC.
GRCL <NR1>
Function
Parameters
Returns
GRST
Function:
Returns
Restores the power supply settings from a stored memory location (locations 1,
2, 3 or 4), previously stored by the SAV command
1,2,3,4. RCL without a parameter restores the power supply settings stored in
the memory location 1
Returns the power supply operation mode.
If power supply is off, returns OFF.
If power supply is on, returns CV for Constant Voltage, CC for Constant Current,
or CP for Constant Power
<DSC> OFF|CV|CC|CP
Returns the Master/Slave setting
Single, Master + # (# - number of slaves units connected) or Slave
<SRD> SINGLE|MASTER+#|SLAVE
Refer to RCL command description.
1,2,3,4
No reply
Refer to RST command description.
No reply
NOTE
89