4.14.6

Output Subsystem

OUTPut[:STATe] <Bool>
Function
Parameter
Query
Return
OUTPut:ENA[:STATe] <Bool>
Function
Parameter
Query
Return
OUTPut:ENA:POLarity <DSC>
Function
Parameter
Query
Return
OUTPut:ILC[:STATe] <Bool>
Function
Parameter
Query
Return
OUTPut:MODE?
Query
Return
Enables / Disables the power supply output Setting.
Query returns an actual output status.
0|1, OFF|ON
OUTPut[:STATe]?
<Bool> 0|1
Enables / Disables the ENA function.
If disabled, power supply ignores the ENA pin signal (J1-10).
0|1, OFF|ON
OUTPut:ENA[:STATe]?
<Bool> 0|1
Sets the ENA signal polarity.
NORM - (same as interlock) - Output ON if ENA pin signal (J1-10) is low
('0').
REV - Output ON if ENA pin signal (J1-10) is high ('1').
0|1, REV|NORM
OUTPut:ENA:POLarity?
<DSC> REV|NORM
Enables / Disables the ILC function.
If disabled, power supply ignores the ILC pin signal (J1-19).
0|1, OFF|ON
OUTPut:ILC[:STATe]?
<Bool> 0|1
Returns the power supply operation mode.
If power supply output is OFF, returns OFF.
If power supply output is ON, returns the CV for Constant Voltage, CC for
Constant Current, or CP for Constant Power Limit.
<DSC> OFF|CV|CC|CP
106