OUTPut:RELay2[:STATe] <Bool>
Function
Parameter
Query
Return
OUTPut:TTLTrg:MODE <DSC>
Function
Parameter
Query
Return
4.14.7

Program Subsystem

[PROGram]:COUNter <NR1> | INFinity
Function
Parameters
Query
Return
[PROGram]:LIST:CURRent <NRf+>,{<NRf+>}
Function
Parameters
Unit
Query
Return
Example
A delay of ~100mSec is required after the [PROGram]:LIST:CURRent command if long
sequences are used, prior sending any additional command.
Sets PROG_OUT_2 pin (J1-20) in a rear panel connector. 0 – MOSFET is ON.
1 – MOSFET is OFF.
0|1, OFF|ON
OUTPut:RELay2[:STATe]?
<Bool> 0|1
Sets the operation mode of the Trigger Out signal to OFF, FSTR, or TRIG
mode.
Programming Mode - NONE:
In TRIG mode, a trigger is generated if output state changes.
In FSTR mode, an output pulse is generated automatically any time an
output parameter, such as output state, voltage, or current is
programmed.
Programming Modes - LIST or WAVE:
In TRIG mode, a trigger is generated if LIST or WAVE has completed.
In FSTR mode, an output pulse is generated automatically any time a
step has completed.
0|1|2, OFF|FSTR|TRIG
OUTPut:TTLTrg:MODE?
<DSC> OFF|FSTR|TRIG
Sets the sequencers' iterations counter
1 ~ 9999. Any number greater than 9999 is interpreted as INFinity.
Use INFinity if you wish to execute a sequence indefinitely.
[PROGram]:COUNter? (if COUNter > 9999, the response is INF)
<NR1>| INF
Specifies the output current points in a list.
Current points are separated by commas.
The function accepts up to 100 parameters.
The range is limited by the power supply current programming range.
A
[PROGram]:LIST:CURRent?
<NR2>,{<NR2>} 5-digits format.
LIST:CURR 2.5,3.0,3.5; LIST:CURR MAX,2.5,MIN
NOTE
108