4.2.3

Address Setting

The power supply address can be set to any address in the range of 0 to 31.
9.
Press the COMM button.
COMM LED illuminates. INTFC message appears on the Voltage display.
10.
Rotate the Voltage encoder 1 step clockwise.
ADR message appears on the Voltage display.
11.
Rotate the Current encoder to select the required address: 0...31.
12.
Press the Current encoder to accept a parameter.
When the parameter is accepted, the display blinks once.
13.
To exit the menu, press the COMM button or the BACK button.
4.2.4

IP Address Setting

The power supply IP address setting is split into four fields: IP1.IP2.IP3.IP4. These four fields
represent an IPv4 address. Each IP field can be set to any value in the range of 0 to 255.
1.
Press the COMM button.
COMM LED illuminates. INTFC message appears on the Voltage display.
2.
Rotate the Voltage encoder 2 steps clockwise.
IP message appears on the Voltage display.
3.
Rotate the Current encoder to select a required IP address field: IP1, IP2, IP3 or IP4.
4.
Press Current encoder to accept a parameter.
When the parameter is accepted, the display blinks once.
5.
Rotate the Current encoder to select the required IP address: 0...255 *.
6.
Press the Current encoder to accept the parameter.
When the parameter is accepted, the display blinks once.
7.
To exit the menu, press the COMM button or the BACK button twice.
The IP Address Setting is available only if the LAN communication interface is selected.
* IP Address update step is set by Coarse or Fine mode selection. In Coarse mode, IP address
field is updated in steps of 10 addresses. In Fine mode, IP address field is updated in step of one
address. Use the FINE button on the Front Panel to toggle between modes (Coarse or Fine).
NOTES