*TST?
Query
Returns
*WAI
Function
ABORt
Function
4.14

SCPI Subsystem Commands

Subsystem commands are specific to power supply functions. Those can be a single command or
a group of commands. Groups are comprised of commands that extend one or more levels below
the root.
Commands followed by a question mark (?) take only the query form.
4.14.1

Display Subsystem

DISPlay[:WINDow]:STATe <Bool>
Function
Parameter
Query
Return
Display & Buttons are active after AC recycle or after Power Switch OFF (above four seconds at
Power Switch OFF state).
DISPlay[:WINDow]:FLASh <Bool>
Function
Parameter
Query
Return
DISPlay[:WINDow]:TEST <Bool>
Function
Parameter
Self-test query. If one or more tests fail, "1" is returned. Error is stored in the
error queue.
<Bool> 0|1
Configures the instrument to wait for all pending operations to complete before
executing any additional commands over the interface.
This command cancels any sequencer actions in progress. It returns the trigger
system to the Idle state.
TWI bit is cleared in the Status Register Group Condition Register.
Sets front panel (Display, Buttons) OFF/ON.
Power switch is active, disregarding command OFF/ON state.
0|1, OFF|ON
DISPlay[:WINDow]:STATe?
<Bool> 0|1
Blink Display
0|1, OFF|ON
DISPlay[:WINDow]:FLASh?
<Bool> 0|1
Turns all display segments & LEDs on.
0|1, OFF|ON
NOTE
103