1. If FRST function is performed by communication command, power supply loses
communication due to communication settings change and addressing is lost. Firmware
02.106 and above has the ability to select communication interface following factory reset
operation. Refer to section 4.14.10, SYSTem:FRST <DSC> command.
2. Press and hold Reset Button located on the rear panel to perform reset function (refer to Table
1-4, Reset Button).
2.13.2

Reset

This function sets basic parameters to their default state (as defined in Table 2-6).
It is set via communication only. The following states are cleared: OVP, Foldback and UVP.
2.13.3

Last Setting Memory

Last setting stores power supply state into the non-volatile memory. Stored settings are defined in
Table 2-6. Settings are stored at AC fault condition. Settings are restored at power supply AC ON.
2.13.4
Save <1..4>
This function stores parameters into the non-volatile memory. It is set via the Front Panel or
communication.
User can save up to 4 sets of parameters. Refer to Table 2-6 for available Store parameter sets.
To save the Front Panel setting, perform the following steps:
1.
Press the SYST button. SYST (GREEN) LED illuminates. Rotate Voltage encoder until SAVE 1
appears.
2.
Rotate Current encoder to select the desired memory cell (1-4). Accept by pressing Current
encoder. The display blinks once to acknowledge the setting.
3.
Exit the SYST menu by pressing the Back button or the SYST button.
2.13.5
Recall <1..4>
This function recalls parameters from the non-volatile memory. It is set via the Front Panel or
communication.
User can recall up to 4 sets of parameters. Refer to Table 2-6 for available Recall parameter sets.
To recall the Front Panel setting, perform the following steps:
1.
Press the SYST button. SYST (GREEN) LED illuminates. Rotate Voltage encoder until RECAL 1
appears on the display.
2.
Rotate Current encoder to select the desired memory cell (1-4). Accept by pressing Current
encoder. The display blinks once to acknowledge the setting.
3.
Exit the SYST menu by pressing the Back button or the SYST button.
NOTES