Status Commands - TDK-Lambda GH10-100 User Manual

Table of Contents

Advertisement

APR <DSC>
Function
Parameters
Query
Returns
REL1 <Bool>
Function
Parameter
Query
Return
REL2 <Bool>
Function
Parameter
Query
Return
4.10.9

Status Commands

Refer to section 6.3.1 for GEN Registers tree.
STT?
Query
Example
FLT?
Query
Returns
Example
FENA <NRh>
Function
Parameters
Query
Returns
Set the power supply analog programming & monitoring range.
Programming – 5/10 volt or 5/10kΩ.
Monitoring – 5/10 volt
5|10
APR?
<DSC> 5|10
Set the Programmable Pin 1 state (J1.21). 0 – MOSFET ON. 1 – MOSFET OFF.
0|1, OFF|ON
REL1?
<Bool> 0|1
Set the Programmable Pin 2 state (J1.20). 0 – MOSFET ON. 1 – MOSFET OFF.
0|1, OFF|ON
REL2?
<Bool> 0|1
Reads the complete power supply status.
Returns ASCII characters representing the following data, separated by commas.
MV<actual (measured) voltage>,PV<programmed (set) voltage>,
MC<actual (measured) current>,PC<programmed (set) current>,
SR<status condition register>,FR<fault condition register>
MV(10.000),PV(10.000),MC(04.000),PC(05.000),SR(04ff),FR(00C0)
Returns the value of the Questionable Group Condition register, a read-only
register holding the real-time power supply faults.
<NRh>
09FA
Sets the value of the Questionable Group Enable register. This register is a mask
to enable specific bits from the Condition register to the Event register.
0...FFFF
FENA?
<NRh> 0...FFFF
93