4.10.8

Auxiliary Commands

BOOL <DSC>
Function
Parameters
Query
Returns
BOOL <DSC> command is available from firmware revision 02.110.
LANG <DSC>
Function
Parameter
RIE <Bool>
Function
Parameters
Query
Returns
PVS <DSC>
Function
Parameters
Query
Returns
PCS <DSC>
Function
Parameters
Query
Returns
Select query Return format of Boolean (<Bool>) commands.
DIGIT – Boolean queries are replied with 0|1.
TEXT – Boolean queries are replied with OFF|ON.
DIGIT|TEXT, 0|1
BOOL?
<DSC> DIGIT|TEXT
Sets the communication protocol to SCPI language.
SCPI
Enable / Disable ILC function. If disabled, power supply ignores the ILC pin
state.
0|1, OFF|ON
RIE?
<Bool> 0|1
Set the Voltage programming source: Front Panel, External Resistor, or
External Voltage.
0|1|2 or DIG|VOL|RES
PVS?
<DSC> DIG|VOL|RES
Set the Current programming source: Front Panel, External Resistor, or External
Voltage.
0|1|2 or DIG|VOL|RES
PCS?
<DSC> DIG|VOL|RES