4.14.4
Global Subsystem
Global Commands General
Power Supplies acting upon Global Commands don't have to be addressed.
•
•
All Power Supplies attached to the Interface must be capable of accepting Global Commands.
•
Global commands have no reply, execution only.
GLOBal:*RCL <NR1>
Function
Parameters
GLOBal:*RST
Function:
GLOBal:*SAVe <NR1>
Function
Parameters
GLOBal:CURRent[:AMPLitude] <NRf+>
Function
Units
GLOBal:OUTPut[:STATe] <Bool>
Function
Parameter
GLOBal:VOLTage[:AMPLitude] <NRf+>
Function
Units
4.14.5
Measure Subsystem
MEASure:CURRent[:DC]?
Query
Return
MEASure:VOLTage[:DC]?
Query
Return
MEASure:POWer[:DC]?
Query
Return
Refers to *RCL <NR1> command description.
1,2,3,4
Refers to *RST command description.
Refers to *SAV <NR1> command description.
1,2,3,4
Refers to [SOURce]:CURRent[:LEVel][:IMMediate][:AMPLitude] <NRf+>
command description.
A
Refers to OUTPut[:STATe] <Bool> command description.
0|1, OFF|ON
Refers to [SOURce]:VOLTage[:LEVel][:IMMediate][:AMPLitude] <NRf+>
command description.
V
Returns a measured output current.
<NR2> - Current in Amperes, 5 digits format.
Returns a measured output voltage.
<NR2> - Voltage in Volts, 5 digits format.
Returns a measured output power.
<NR2> - Power in Watts, 5 digits format.