This chapter shows you how to install hardware for a freestanding or rack-mounted scenario.
4.1

Environment

The following are the recommended environments for the IES-1000.
4.1.1
Operating Environment
Temperature: 0 — 50°C; Humidity: 5% — 95% (non-condensing)
4.1.2
Storage Environment
Temperature: -25 - 70°C; Humidity: 5% - 95% (non-condensing)
4.2

Freestanding IES-1000 Installation Requirements

Position the IES-1000 on a flat surface. Remember that the unit requires proper ventilation.
4.3

Rack-mounted IES-1000 Installation Requirements

Two mounting brackets (supplied).
Eight M3 flat head screws (supplied) and a #2 Philips screwdriver.
Four M5 flat head screws and a #2 Philips screwdriver.
4.4
Mounting the IES-1000 on a Rack
Precautions:
Make sure the rack will safely support the combined weight of all the equipment it contains.
Make sure the position of the IES-1000 does not make the rack unstable or top-heavy. Take all
necessary precautions to anchor the rack securely before installing the unit.
Hardware Installation
Refer also to the Hardware Specifications Appendix.