Inverting Operation; Output Coil - Delta Electronics AC Motor Drive VFD-E User Manual

Vfd-e high performance/flexible options/micro type ac motor drives
Table of Contents

Advertisement

Appendix D How to Use PLC Function|
Mnemonic
INV
Operand
Explanations:
Inverting the operation result and use the new data as an operation result.
Program Example:
Ladder diagram:
X0
Mnemonic
OUT
Operand
Explanations:
Output the logic calculation result before the OUT command to specific device.
Motion of coil contact
Operation
result
FALSE
TRUE
D-36
Y1
X0~X17
Y0~Y17
--
Coil
A contact (normally open)
OFF
Non-continuity
ON
Continuity
Function

Inverting Operation

None
Command code: Operation:
LD
X0
Load A contact of X0
INV
Inverting the operation result
OUT
Y1
Drive Y1 coil
Function

Output coil

M0~M159
OUT command
Contact
B contact (normally closed)
Continuity
Non-continuity
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
T0~15
C0~C7
--
--
D0~D29
--