Delta Electronics AC Motor Drive VFD-E User Manual page 70

Vfd-e high performance/flexible options/micro type ac motor drives
Table of Contents

Advertisement

Parameter
Explanation
Over-Current Stall
06.02
Prevention during
Operation
Over-Torque
06.03
Detection Mode
(OL2)
Over-Torque
06.04
Detection Level
Over-Torque
06.05
Detection Time
Electronic Thermal
Overload Relay
06.06
Selection
Electronic Thermal
06.07
Characteristic
Present Fault
06.08
Record
06.09
Second Most
Recent Fault Record
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
Settings
0:Disable
20 to 250%
0: Disabled
1: Enabled during constant speed operation.
After the over-torque is detected, keep
running until OL1 or OL occurs.
2: Enabled during constant speed operation.
After the over-torque is detected, stop
running.
3: Enabled during accel. After the over-torque
is detected, keep running until OL1 or OL
occurs.
4: Enabled during accel. After the over-torque
is detected, stop running.
10 to 200%
0.1 to 60.0 sec
0: Standard motor (self cooled by fan)
1: Special motor (forced external cooling)
2: Disabled
30 to 600 sec
0: No fault
1: Over current (oc)
2: Over voltage (ov)
3: IGBT Overheat (oH1)
4: Power Board Overheat (oH2)
5: Overload (oL)
6: Overload1 (oL1)
7: Motor over load (oL2)
8: External fault (EF)
9: Current exceeds 2 times rated current
during accel.(ocA)
Chapter 4 Parameters|
Factory
Setting
170
0
150
0.1
2
60
0
Customer
4-17