Acceleration S-Curve; Deceleration S-Curve - Delta Electronics AC Motor Drive VFD-E User Manual

Vfd-e high performance/flexible options/micro type ac motor drives
Table of Contents

Advertisement

During Auto deceleration, regenerative energy is measured and the motor is smoothly stopped
with the fastest deceleration time.
But when this parameter is set to 04, the actual accel/decel time will be equal to or more than
parameter Pr.01.09 ~Pr.01.12.
Auto acceleration/deceleration makes the complicated processes of tuning unnecessary. It
makes operation efficient and saves energy by acceleration without stall and deceleration
without brake resistor.
In applications with brake resistor or brake unit, Auto deceleration shall not be used.
01.17

Acceleration S-Curve

01.18

Deceleration S-Curve

Settings
This parameter is used to ensure smooth acceleration and deceleration via S-curve.
The S-curve is disabled when set to 0.0 and enabled when set to 0.1 to 10.0/0.01 to 10.00.
Setting 0.1/0.01 gives the quickest and setting 10.0/10.00 the longest and smoothest S-curve.
The AC motor drive will not follow the Accel/Decel Times in Pr.01.09 to Pr.01.12.
The diagram below shows that the original setting of the Accel/Decel Time is only for reference
when the S-curve is enabled. The actual Accel/Decel Time depends on the selected S-curve
(0.1 to 10.0).
The total Accel. Time=Pr.01.09 + Pr.01.17 or Pr.01.11 + Pr.01.17
The total Decel. Time=Pr.01.10 + Pr.01.18 or Pr.01.12 + Pr.01.18
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
0.0
0.1 to 10.0/0.01 to 10.00
1
3
1
3
1 2
Disable S curve
Acceleration/deceleration Characteristics
Chapter 4 Parameters|
S-curve disabled
S-curve enabled (10.0/10.00 is the smoothest)
2
2
4
3 4
Enable S curve
Unit: 0.1/0.01
Unit: 0.1/0.01
Factory Setting: 0
4
4-47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents