Group 13: PG function Parameters for Extension Card
Parameter
Explanation
13.00
PG Input
13.01
PG Pulse Range
Motor Pole Number
13.02
(Motor 0)
Proportional Gain
13.03
(P)
Integral Gain (I)
13.04
Speed Control
Output Frequency
13.05
Limit
Speed Feedback
13.06
Display Filter
Detection Time for
Feedback Signal
13.07
Fault
Treatment of the
Feedback Signal
13.08
Fault
Speed Feedback
13.09
Filter
Source of the High-
13.10
speed Counter
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
Settings
0: Disabled
1: Single phase
2: Forward/Counterclockwise rotation
3: Reverse/Clockwise rotation
1 to 20000
2 to 10
0.0 to 10.0
0.00 to 100.00 sec
0.00 to 100.00Hz
0 to 9999 (*2ms)
0.0: disabled
0.1 to 10.0 sec
0: Warn and RAMP to stop
1: Warn and COAST to stop
2: Warn and keep operation
0 to 9999 (*2ms)
0: PG card
1: PLC (NOT for VFD*E*C models)
Chapter 4 Parameters|
Factory
Setting
0
600
4
1.0
1.00
10.00
500
1
1
16
Read
Only
Customer
4-31