Chapter 4 Parameters|
Weights
Bit
The Setting method is convert binary number to decimal number for input.
For example: if setting MI3, MI5, MI6 to be internal terminals and MI1, MI2, MI4 to be external
terminals. The setting value should be bit5X2
32+16+4=52 as shown in the following.
When extension card is installed, the number of the multi-function input terminals will increase
according to the extension card. The maximum number of the multi-function input terminals is
shown as follows.
Weights
Bit
04.28

Internal Terminal Status

Settings
This parameter is used to set the internal terminal action via keypad, communication or PLC.
4-86
5
4
3
Weights
1
1
0
Bit
11
10
9
8
7
0 to 4095
0=external terminal
1=internal terminal
2
1
0
MI1
MI2
MI3
MI4
MI5
MI6
5
4
+bit4X2
+bit2X2
0=external terminal
1=internal terminal
1
0
0
MI1
MI2
MI3
MI4
MI5
MI6
6
5
4
3
2
1
0
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
2
5
4
2
= 1X2
+1X2
+1X2
0=external terminal
1=internal terminal
MI1
MI2
MI3
MI4
MI5
MI6
MI7
MI8
MI9
MI10
MI11
MI12
Factory Setting: 0
=
Unit: 1