Mnemonic
CNT
Operand
Explanations:
1.
When the CNT command is executed from OFF ON, which means that the counter coil
is driven, and 1 should thus be added to the counter's value; when the counter achieved
specific set value (value of counter = the setting value), motion of the contact is as follows:
2.
If there is counting pulse input after counting is attained, the contacts and the counting
values will be unchanged. To re-count or to conduct the CLEAR motion, please use the
RST command.
Program Example:
Ladder diagram:
X0
CNT
Mnemonic
MC / MCR
Operand
Explanations:
1.
MC is the main-control start command. When the MC command is executed, the
execution of commands between MC and MCR will not be interrupted. When MC
command is OFF, the motion of the commands that between MC and MCR is described
as follows:
Timer
Accumulative timer
Subroutine timer
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
C-K
C0~C7, K0~K32,767
C-D
C0~C7, D0~D29
NO(Normally Open) contact
NC(Normally Closed) contact
Command code: Operation:
LD
C20
K100
CNT

Master control Start/Reset

N0~N7
The counting value is set back to zero, the coil and the contact
are both turned OFF
The coil is OFF, and the timer value and the contact stay at their
present condition
The counting value is back to zero. Both coil and contact are
turned OFF.
Appendix D How to Use PLC Function|
Function

16-bit counter

Continuity
Non-continuity
X0
Load contact A of X0 C2 counter
C2 K100
Setting is K100
Function