Brake Release Frequency; Brake Engage Frequency; Display The Status Of Multi-Function Output Terminals - Delta Electronics AC Motor Drive VFD-E User Manual

Vfd-e high performance/flexible options/micro type ac motor drives
Table of Contents

Advertisement

03.11

Brake Release Frequency

Settings
03.12

Brake Engage Frequency

Settings
These two parameters are used to set control of mechanical brake via the output terminals
(Relay or MO1) when Pr.03.00~03.01 is set to 21. Refer to the following example for details.
Example:
1. Case 1: Pr.03.12 ≥ Pr.03.11
2. Case 2: Pr.03.12 ≤ Pr.03.11
Frequency
Output
Case 1: Pr.03.12
Pr. 03.11
Case 2: Pr.03.12
Run/Stop
Case 1: MO1=21
Case 2: MO1=21
Note: MO1: setting value of Pr.03.01
03.13

Display the Status of Multi-function Output Terminals

Settings
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
0.00 to 600.0Hz
0.00 to 600.0Hz
Read Only
Bit0: RLY Status
Bit1: MO1 Status
Bit2: MO2/RA2 Status
Bit3: MO3/RA3 Status
Bit4: MO4/RA4 Status
Bit5: MO5/RA5 Status
Chapter 4 Parameters|
Factory Setting: 0.00
Factory Setting: 0.00
Time
Factory setting: ##
Unit: 0.01
Unit: 0.01
4-67

Hide quick links: