Frame B and C Mounting Clearances
Option 1 (-10 to +50°C)
150mm
150mm
For VFD-E-P series: heat sink system example
Control panel
AC motor drive
CAUTION!
1.
Operating, storing or transporting the AC motor drive outside these conditions may cause
damage to the AC motor drive.
2.
Failure to observe these precautions may void the warranty!
3.
Mount the AC motor drive vertically on a flat vertical surface object by screws. Other directions
are not allowed.
4.
The AC motor drive will generate heat during operation. Allow sufficient space around the unit
for heat dissipation.
Revision June 2008, 04EE, SW--PW V1.11/CTL V2.11
Option 2 (-10 to +40°C)
150mm
Air-extracting apparatus
Duct temperature
40
Air flow speed
2m/sec
dust collector
fan
Chapter 1 Introduction|
150mm
User
's heat sink should comply
C
with following conditions:
1. Flatness <0.1mm
2. Roughness <6um
3. Grease 10um~12um
4. Screw torque: 16Kgf-cm
5. Recommended temperature <80
Air flow
Air Flow
C
1-9