Chapter 7. Modules Terminal Menu
» Type
» Menu
» Alarm
» Test
» State
7-2
Write security:3; Read security:5
Displays the type of module actually installed in the slot or the type of
module you plan to install in the slot. The ATLAS 800
detects the type of module installed in each slot, and the
ically defaults to the installed module type. You can also use this field to
pre-configure a unit before actually installing modules by specifying the
module that you want to install in each slot.
To use this option, navigate to the field you want to edit and press
empty slots, a list of all the available module types displays. Select the one
you want and it displays in the
with a module, you can only set this field to
If you install a module in a slot, then want to install a different type of
module in the slot, you must set this field to Empty before selecting
another module type.
If a module is installed, the module type automatically shows the
name of the installed module, and it cannot be set to any other option.
Displays additional status and configuration menus for the selected module.
To access the submenus for this item, use the
column for the module you want to edit, and press
mation on each submenu item, see Modules (Quad T1/PRI) Menu on page 7-3.
Read security:5
Displays whether there is an alarm condition on the ATLAS 800
Unit. Press
to access the Alarm menu.
Enter
Read security:5
Displays whether the ATLAS 800
choose the Menu submenu on this screen. Then, select the
access the screen that allows you to set up and initiate tests. See Test on page
7-2 for details. Press
Enter
Read security:5
Displays whether the module is online of offline. Even though a module is
physically installed, it must be marked
available resource. This parameter allows an installed module to be marked
, which may be useful in system troubleshooting. If you choose
Offline
, the module will not be in alarm condition, but will display
Offline
Once a module is installed, you must change the state to Online in
order for the ATLAS to utilize the module for any data bandwidth.
PLUS
ATLAS 800
field. If this field is already configured

Type

Empty
Arrow Keys
PLUS
is executing a test. To initiate a test,
to access the Test menu.
for it to be considered an
Online
User Manual
PLUS
automatically
field automat-
Type
. For
Enter
.
to scroll to the

Menu

. For detailed infor-
Enter
PLUS
Base
option to

Test

.
Offline
61200226L1-1