REVIEW THE REAR PANEL DESIGN

Control/Chain Out
Connects to Chain
In of another unit
Control/
Chain In
Interface of
Chain In
CONTROL
/CHAIN
IN
OUT
10 BASE T
1
2
3
4
ALL EMPTY SLOTS MUST BE COVERED WITH BLANK PANELS
Blank panel covering an
unused option slot
61200226L1-1
The supplementary equipment grounding conductor shall not be smaller in
size than the ungrounded branch-circuit supply conductors. The supple-
mentary equipment grounding conductor shall be connected to the product
at the terminal provided, and shall be connected to ground in a manner that
will retain the ground connection when the product is unplugged from the
receptacle. The connection to ground of the supplementary equipment
grounding conductor shall be in compliance with the rules for terminating
bonding jumpers at Part K or Article 250 of the National Electrical Code,
ANSI/NFPA 70. Termination of the supplementary equipment grounding
conductor is permitted to be made to building steel, to a metal electrical race-
way system, or to any grounded item that is permanently and reliably con-
nected to the electrical service equipment ground.
PLUS
The ATLAS 800
rear panel contains eight slots for housing option mod-
ules which provide a variety of additional resources and data ports. All slots
are functionally identical, except slots 7 and 8. These slots can also accom-
modate an optional power supply for redundancy Figure 2-1 (AC powered
unit) and Figure 2-2 (DC powered unit).
MON (Monitor)
10 Base T
Bantam test jack
RJ-48C Connec-
tion Port
CAUTION: MAINTENANCE TO BE PERFORMED BY TRAINED SERVICE PERSONNEL ONLY
5
6
7
8

Figure 2-1. AC Powered ATLAS 800

PLUS
ATLAS 800
Chapter 2. Installing the ATLAS 800PLUS
NTWK1
RJ-48C Connec-
tion Port
RJ-48C Connection
NTWK 1 NTWK 2
MON
CAUTION-RISK OF
SUPPLAMENTAL EARTH GROUND MUST BE CONNECTED
ELECTRIC SHOCK
PRIOR TO CONNECTION OF TELECOMMUNICATION WIRING
User Manual
NTWK2
Port
Power Switch
CAUTION:
REMOVE POWER CORD PRIOR TO
REMOVAL OF POWER SUPPLY
I
O
90-130/190-240VAC
4A/2A, 50/60 HZ
4A/25OV SLOBLO
CAUTION: FOR CONTINUED PROTECTION
AGAINST RISK OF FIRE REPLACE ONLY
WITH SAME TYPE AND RATING OF FUSE.
Supplemental
earth ground lug
PLUS
Rear Panel
2-3