Chapter 6. Terminal Menu and System Control
»» Active
» Bonding Config
»» TXINIT Timer
»» TXFA Timer
»» TXADD01 Timer
»» TXDEQ Timer
»» TANULL Timer
6-12
Instructions for Changing Passwords
Step
1
Select the Password field—a new Password field displays.
2
Type the new password in the Enter field.
3
Type the new password again in the Confirm field.
The password can contain up to 12 alphanumeric characters.
You can also use spaces and special characters in the
password.
Write security: 0; Read security: 5
Displays the number of users for each label that are currently logged into
the system.
Write security: 5; Read security: 5
Displays the configuration submenus available for the IMUX Nx56/64
modules. This configuration is shared among all IMUX modules.
Write security: 3; Read security: 5
Specifies the length of time the originating endpoint attempts to detect the
BONDING negotiation pattern from the answering endpoint before decid-
ing the BONDING call has failed.
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to detect the BONDING
frame pattern when a call is connected before deciding the BONDING call
has failed. When interoperating with other manufacturers' BONDING
equipment, it may be necessary to change this time so that it matches
TXADD01.
Write security: 3; Read security: 5
Specifies the length of time both endpoints wait for additional calls to be
connected at the end of negotiation before deciding that the BONDING call
has failed. The factory default setting is sufficient for most calls to connect,
although when dialing overseas it may be necessary to lengthen this timer
to allow for slower call routing.
Write security: 3; Read security: 5
Specifies the length of time both endpoints attempt to equalize the network
delay between the bearer channels before deciding the BONDING call has
failed.
Write security: 3; Read security: 5
Specifies the length of time the answering endpoint attempts to detect the
BONDING negotiation pattern from the originating endpoint before decid-
ing the BONDING call has failed. It may be necessary to shorten this timer
if the DTE equipment using the BONDING module also has timer con-
straints for completing non-BONDING parameter negotiation.