Appendix A. System Event Logging
Event
System Cold Start
Generated 5 seconds after the
completion of system initialization.
SNMP Authentication Failure
Generated if the ATLAS receives
an SNMP request from an SNMP
manager defined in the ATLAS
SNMP Communities list but with a
community name that does not
match the community name
defined in the SNMP Communities
list.
Module removed or not
responding
Module found
Console login failure
Three consecutive login attempts
were attempted and failed
ATLAS 800 configuration file
loaded into the system and
activated
The internal system temperature
is too high
The internal system temperature
has returned to norma
The primary power supply is
present but is not operating
properly
The primary power supply is
operating properly or has been
removed
The backup power supply is
present but is not operating
properly
The backup power supply is
operating properly or has been
removed
A-2
Category
Console Log String
Normal
Cold Start
Info
SNMP Authentication
Failure
Warning
Module Not Responding
Information
Module Found
Minor
Login Failure
Critical
System Configuration
Uploaded
Critical
Internal Temperature
Warning
Critical
Internal Temperature
Warning Cleared
Critical
Main Power Supply Failure PS1 WARNING -A
Critical
Main Power Supply Failure
Cleared
Critical
Backup Power Supply
Failure
Critical
Backup Power Supply
Failure Cleared
PLUS
ATLAS 800
User Manual
Table A-1. Source: System
Front Panel Display
String
COLD START
AUTHEN FAIL
MODULE OUT -A
MODULE FOUND
LOGIN FAILURE
CONFIG UPLOADED
TEMP WARN -A
TEMP WARN -I
PS1 WARNING -I
PS2 WARNING -A
PS2 WARNING -I
61200226L1-1