Caller Id Number; Strip Msd; Source Id; Quad Nx56/64 Module (User Termination) - ADTRAN ATLAS 800 PLUS User Manual

Hide thumbs Also See for ATLAS 800 PLUS:
  • Q&a (22 pages)
Table of Contents

Advertisement

» Caller ID Number
»» Strip MSD
»» Source ID

QUAD NX56/64 MODULE (USER TERMINATION)

61200226L1-1
Write security: 3; Read security: 5
Defines the number for ATLAS to use to provide Caller ID to the Network
for outgoing calls sent through this end point. This option only displays if
Direct Inward Dialing is set to
The Caller ID number must be specific (i.e., no "wild cards").
Write Security: 3 Read Security: 5
This option allows a selected quantity of the Most Significant Digits (MSD)
of a dialed number to be stripped prior to being forwarded out of the port.
For example, a User port could be set to accept all calls beginning with 8
(8$), and then with Strip MSD set to 1, all digits would be sent toward the
network except the leading 8.
The Strip MSD parameter does not affect the Call Accept criteria.
All of the digits (including the MSDs that are subsequently
stripped) are used as accept criteria.
Write security: 3; Read security: 5
The Source ID field simplifies the creation of a Dial Plan in applications
where the criteria for switching calls to a certain end point is a function of
which endpoint originated the call.
Default value = 0. The default ID for all end points is 0 and all accept # s
is 0. With default values, all calls are routed based only on dialed num-
ber.
Multiple end points can have the same Source ID.
When creating the Call Accept list, specify a Source ID (s) as well as a
dialed number or range of dialed numbers to accept.
For example, an application requires that all calls that originate from Port 1
of the Quad T1/PRI module in Slot 1 be switched to Port 4 of that same mod-
ule. Assign a unique Source ID (e.g. 7) to Port 1 of the module, and then con-
figure Port 4 to only accept calls from that unique Source ID (7).
The Quad Nx56/64 can only serve as a user termination end point.
When you are working in the User Termination section of the Dial Plan
menu, and the Slot is defined as a QuadNx56/64 module, the following in-
terface configuration options are available:
PLUS
ATLAS 800
Chapter 10. Dial Plan Terminal Menu
. This item is optional.
Disabled
User Manual
.
10-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

1200226l11200228l1

Table of Contents