Dedicated Circuit Backup and Circuit Status
Chapter 9

OVERVIEW

Dedicated Circuit Dial Backup Setup

61200226L1-1
This chapter describes the configuration of dedicated circuits for backup and
discusses the Circuit Status menu.
In Figure 9-1, the host ATLAS 800
to the T1 cloud, which is then DACSed out to two different remote sites, 8
DS0s each.
504K
Frac T1 16DS0s
512K

Figure 9-1. Dedicated Circuits Backup Configuration

Dedicated circuit backup allows the user to configure the ATLAS to dial up
a backup link when the dedicated link goes into alarm. Additionally, the AT-
LAS Nx 56/64 V.35 and USSI modules can rob an inband 8kbps channel over
which messages can be transferred. When the ATLAS loses communication
with the remote site, backup will be initiated. This feature is compatible
with the Inband Mode of the ADTRAN TSU series of products.
Currently, dedicated circuit backup is supported only for Nx interfaces
(V.35 or USSI) nailed to T1s.
PLUS
ATLAS 800
PLUS
has a fractional T1 of 16 DS0s going
Frac T1 8DS0s
T1
Frac T1 8DS0s