Current Update Status; Previous Update Status; Begin Firmware Update - ADTRAN ATLAS 800 PLUS User Manual

Hide thumbs Also See for ATLAS 800 PLUS:
  • Q&a (22 pages)
Table of Contents

Advertisement

»» Current Update
Status
»» Previous Update
Status
»» Begin Firmware
Update
61200226L1-1
Restart at Specified
Date and Time
Restart Date and Time
Restart at Specified Date and Time is only available for the
System Controller— not for modules residing in expansion slots,
since they are unable to maintain normal operation during the update
process.
Read security: 5
Indicates progress or problems encountered during the current update pro-
cess. The field displays Idle if no update is in progress or when the update
is successfully completed. At the end of a successful update, the contents of
this field are copied into Previous Update Status .
If you are updating several modules at the same time (if Module Slot is set
to All Modules of a Type ), this option displays
tains submenu items. The following submenus display:
Slt
Indicates the slot number.
Type
Defines the type of module for each slot.
Current Status
Indicates the status of the current update.
Previous
Indicates the status of the previous update.
Status
Previous Time
Indicates the time of the previous update.
During the TFTP upload process, various status messages are provided in
Current Update Status (see Table 11-1 on page 11-5).
Read security: 5
Displays the status of the previous update. If a firmware update has not
been attempted for a particular slot, this field reads,
Following a successful update the field reads,
an update was unsuccessful, the appropriate error message displays.
Write security: 1; Read security: 5
Begins updating the firmware for the selected modules. To start this action,
enter
to begin or enter
Y
the update has begun. For XMODEM updates, cancel the process via the
terminal emulation software (consult your documentation for information
PLUS
ATLAS 800
Chapter 6. Terminal Menu and System Control
Lets you specify a date and time to automatically
restart the updated module. (When you select this
option, a new field called Restart Date and Time
displays below the current field.)
Write security: 1; Read security: 5
Defines the date and time to restart the system.
Enter the time using a 24-hour format (i.e.,
23:00:00 for 11:00 pm).
Enter the date in mm-dd-yyyy format (i.e., 10-
30-1998).
[+]
Module Update Complete.
to cancel. You can also cancel the operation after
N
User Manual
, indicating this field con-
Has not been attempted.
If
6-15

Advertisement

Table of Contents
loading

This manual is also suitable for:

1200226l11200228l1