Chapter 10. Dial Plan Terminal Menu

QUAD T1/PRI MODULE (NETWORK TERMINATION/RBS)

»» First DS0
»» Number of DS0s
»» DS0s Available
»» Signaling Method
10-12
When you are working in the Network Termination section of the Dial Plan
menu, the Slot is defined as a T1/PRI module, and Sig is set to RBS, the fol-
lowing interface configuration options are available:
Write security: 2; Read security: 5
Defines to ATLAS the DS0s which will be used for this endpoint. These are
the DS0s which ATLAS will use to send and receive calls to and from the
Network (PSTN). Outgoing calls which will be allowed or restricted over
these DS0s are set by the Outgoing Call Accept and Reject Numbers dis-
cussed earlier.
Write security: 3; Read security: 5
Specifies the number of DS0s already defined for this endpoint. This field is
read-only.
Read security: 5
Indicates which DS0s of the T1 have been defined in this switched end
point (indicated by "! "), in another switched end point (indicated by "s"),
or in a Dedicated Map (indicated by "n"). The following symbols may dis-
play in this field:
digits
This DS0 is available. The digit that displays in this field repre-
0—9
sents the last digit of the DS0 number.
*
This port is requesting this DS0 for this connection, but the DS0 is
not yet activated.
!
This DS0 is used by this port in this connection and is activated.
s
This DS0 is used in the switched Dial Plan.
S
This DS0 is used in the switched Dial Plan and conflicts with this
connection.
n
This DS0 is already used in this dedicated map.
N
This DS0 is already used in this dedicated map and conflicts with
this connection.
Write security: 3; Read security: 5
This defines to ATLAS the type of signaling to be used across this trunk.
The signaling selected needs to match the signaling being provided by the
Network (PSTN). The available options include E&M Immediate, E&M
Wink, Loop Start, and Ground Start.