Setting the Average Filter
Output measured data as the average value of a preset count.
Set this, for example, to ignore sudden changes in measured value.
Item
Setting item
Average number
Average
of times
 Explorer pane
→ Edit pane
→ Task Settings window : [Filter]
1
Select how many times the latest measured
values are to be averaged before output from
[Average].
Important
When measurement is started, the measurement result is not updated and output until the measured values have
been sampled for the preset average count.
Note
The average filter can also be set by the operating keys on the Sensor Controller.
Setting the Average Filter p.204
ZW-7000 User's Manual
Setting value
1/2/4/8/16/32/64/128/
256/512/
1024(default value)/2048/4096/
8192/16384 [times]
: [Bank] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Description
Switches the average count.
)
Setting the Output Conditions