1
Loosen the two fixing screws using a screwdriver to
remove Analog output terminal block from the
Sensor Controller.
2
Insert the cord to the terminal hole.
• When you use a wire attached rod terminal, you can in-
sert just with Push-IN.
• When using single wire, or stranded wire
Insert the wire deeply in to the terminal hole while
pushing the release button on the side of terminal hole
using a screwdriver.
Important
• After the connection has been established, pull the wire gently, to make sure that the connection has been made
securely.
• Securely fasten the terminal block to prevent injury when you press in the release button with a screwdriver.
• Do not use 24V power terminal block which is used in ZW-CE series.
3
Reinstall the 24 V input terminal block to the Sensor
Controller.
72
Wiring
Release button
ZW-7000 User's Manual