Calculating - Omron ZW-XC7 User Manual

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Steps
Key operation
4-1
4-2
4-3
5
Scaling setting
Setting Scaling p.109
6

Calculating

Performing Calculations p.107
As an example, here is an explanation of the output of the calculation result below.
(Example)
When calculating the amount of convexity and concavity on the object surface from the difference between the
average value and the peaks and outputting this to TASK3
TASK1: Surface peak hold
TASK2: Surface average hold
TASK3: TASK1 - TASK2 setting
• PARAMETER K: 0
• PARAMETER m: 1
• PARAMETER n: -1
• PARAMETERX: TASK1
• PARAMETERY: TASK2
Operating procedure
Steps
Key operation
1
2
200
Setting Measurement Items
Display
Description
Press the
Select "SUR2."
Press the
Select the measurement surface.
The current setting value is displayed on the sub-display.
Press
In this example, select "EDGE2" and press the
Press the
Display
Description
Press and hold the
mode.
Press the
key to return to the previous menu.
/
keys to select "END" and press the
/
key to enter editing mode and the sub-display blinks.
key for two seconds to enter the RUN mode.
key for two seconds to enter the FUNC
/
key to select MEAS, then press the
key.
key.
key.
ZW-7000 User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 series

Table of Contents