Setting a Trigger Delay
Set this to ignore measure values following TIMING input to avoid the influence of bounding or mechanical
vibration when a device is started up.
The delay time (the delay between timing input and the start of sampling) and the sampling time can be set.
TIMING input
Sampling period
Measured value
Item
Setting item
Trigger delay
Trigger delay mode
Delay time
Sampling time
 Explorer pane
→ Edit pane
→ Task Settings window : [Hold]
1
Set the hold mode and trigger.
Setting the Hold Mode p.121
Setting Triggers p.124
2
Check the check box in [Trigger delay]-
[Trigger delay mode].
ZW-7000 User's Manual
ON
OFF
Delay time
Measured values in this time period
is included in the sampling.
Setting value
OFF (default value)/ON
• Internal synchronous measurement
mode
0.02(default value) to 5000[ms]
• External synchronous measurement
mode
1(default value) to 50000[count]
• Internal synchronous measurement
mode
0.02 to 5000[ms]
100(default value)
• External synchronous measurement
mode
1(default value) to 50000[count]
: [Bank] | [(Bank Data Name)] (double click)
: [Task Settings] icon (
Sampling time
Description
Turns the trigger delay ON/OFF.
• Internal synchronous measurement mode
Sets the period(time) between when turns ON
TIMING input and starts sampling.
• External synchronous measurement mode
Measures the measuring count between when
turns ON TIMING input and starts sampling.
• Internal synchronous measurement mode
Set the time when perform the sampling.
• External synchronous measurement mode
Set the measuring count when performs sampling.
)
Setting the Output Conditions
127