Specifications And External Dimensions; Sensor Head - Omron ZW-XC7 User Manual

Confocal fiber type displacement sensor
Table of Contents

Advertisement

9-1

Specifications and External Dimensions

Sensor Head

Specifications
Item
Sensor controller
Measurement center distance
*1
Measuring range
*2
Static resolution
*3
Linearity
Spot diameter (Total measurent
*4
range)
Measuring cycle
Operating ambient illumination
Ambient temperature range
Ambient humidity range
Degree of protection
Vibration resistance (destructive)
Shock resistance (destructive)
Temperature characteristic
LED Safety
Material
Fiber cable length
Fiber cable minimum bend radius
Insulation resistance (Calibration
ROM)
Dielectric strength (Calibration
ROM)
Weight
Accessories
*1:
The measurement range is higher 28
*2:
Capacity value when OMRON standard mirror surface target is measured at the measurement center distance as the average of 16,384
times
When connected with the controller for the Export Control Trade Ordinance (ZW-7000T), the minimum resolution is 0.25
the Sensor head or setting condition.
*3:
Material setting for the OMRON standard mirror surface target: Error from an ideal straight line when measuring on mirror surface.
*4:
Capacity value defined by 1/e
*5:
Temperature characteristic at the measurement center distance when fastened with an aluminum jig between the Sensor Head and the
target and the Sensor Head and the Sensor Controller are set in the same temperature environment.
238
Specifications and External Dimensions
Specifications
ZW-S7010
ZW-7000@
10 mm
±0.5 mm
0.004 μm
±0.45 μm
Within 50 μm dia.
20 μs to 400 μs
Illumination on object surface max.30000 Lx: (incandescent light)
Operation: 0 to +50°C, Storage: -15 to +60°C
(No freezing and condensation)
Operation/storage: 35 or 85% (No condensation)
IP40 (IEC60529)
10 to 150 Hz (half amplitude 0.35 mm), 80 mins in each of X/Y/Z directions
2
150 m/s
, 6 direction, 3 times each (up/down, left/right, forward/backward)
*5
0.6 μm/°C
Risk Group 3 (IEC62471)
Chassis: aluminum die cast
Fiber cable sheath: PVC
Calibration ROM: PC
0.3 m, 2 m (flex-resistant cable)
20 mm
Between case and all terminals: 20 MΩ (by 250 VDC)
Between case and all terminals: 1000 VAC, 50/60 Hz, 1 min
Fiber cable length 0.3m Approx. 170g
Fiber cable length 2m Approx. 180g
Instruction Manual, 2 straps, Calibration ROM fixing screws (M2), Precautions
μ
s than measurement cycle.
2
(13.5%) of the peak optical intensity of the measurement wavelength.
ZW-S7020
20 mm
±1 mm
0.008 μm
±0.9 μm
Within 70 μm dia.
1.1 μm/°C
ZW-S7030
30 mm
±2 mm
0.016 μm
±2.0 μm
Within 100 μm dia.
1.8 μm/°C
μ
m, regardless of
ZW-7000 User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 series

Table of Contents