Table 29. RASlog messages from WWN card audit
Error message
[EM-1220]...M1, ERROR ... A problem was found on one
or both CID cards (x), please run the wwnrecover tool to
get more information and recovery options.
[EM-1221], ... M1, INFO, ... A WWN card has been
inserted, a WWN verification audit will be run to detect
any mismatches or other problems.
[HIL-1650], CHASSIS, ERROR...Unable to detect WWN
card in chassis. Access to WWN halted...
[EM-1222], ... M1, WARNING, ... A WWN card access
problem has been encountered, please run the
wwnrecover tool to get more information and recovery
options.
Recovery is not possible. Please contact Technical
Support for replacement of the corrupted or inaccessible
WWN(s).
The wwnrecover utility must be used to maintain data integrity when replacing one or both WWN cards
using instructions in the WWN card removal and replacement section. To run wwnrecover, log in as
admin and enter the following command:
switch:admin# wwnrecover
For more information on wwnrecover and command syntax, refer to the Fabric OS Command Reference.

Preparing for WWN card replacement

About this task
If the WWN cards require replacement, complete the following steps. Follow electrostatic discharge (ESD)
precautions.
Procedure
1. Open a Telnet session to the device and log in to the active CP blade as admin. The default password
is "password".
2. Verify that you are logged in to the active CP blade. Run the haShow command to determine the active
CP blade.
3. Run the supportSave command on the active CP blade to capture all settings. These settings will be
referenced to verify the settings have been correctly programmed after WWN replacement.
4. Run the following commands on the device before replacing the cards so that the data can be verified
after the replacement:
v licenseidshow
v ipaddrshow
v switchname
v chassisname
v wwncardshow ipdata
v chassisshow (look at the WWN and chassis information at the bottom)
v ficonshow switchrnid (FICON/mainframe environments only)
v configupload -all
v configupload -vf
Issue
Some kind of error or mismatch has been detected in the
WWN card audit.
A second WWN card is enabled and the WWN card
audit will be run. If an error is detected during the audit,
EM-1220 and EM-1222 messages are generated.
WWN card has been removed from the device. Replace
as soon as possible since system is in degraded state.
An error is detected during normal access to the WWN
cards; typically, one of the cards is corrupted or
inaccessible.
The license ID on the two WWN cards do not match.
153
WWN Cards