IBM SAN256B-6 Installation, Service And User Manual page 271

Storage networking
Table of Contents

Advertisement

Power consumption for HVAC/HVDC power supplies (maximum configuration)
|
|
The maximum power consumption configuration features fans at maximum speed and the FC32-48 blade
installed with optics. Traffic is at full line rate, the smallest packet is 64 bytes, the ambient temperature is
|
40°C (104°F), and maximum power is used for all supported optics. Power specifications do not include
|
the power draw for the SX6 extension blade.
|
Note: Volt-ampere (VA) power measurement is provided only for power consumption using the
|
maximum configuration.
|
|
|
|
|
|
@ 100 VAC
|
| | |
|
Model name
input
|
|
| |
|
SAN256B-6
2889 W
|
|
|
|
9681 Btu/hr
|
|
|
|
|
3010 VA
|
|
|
|
|
|
|
|
| |
|
|
|
SAN512B-6
2438 W
|
|
|
|
8322 Btu/hr
|
|
|
|
|
2540 VA
|
|
|
|
|
|
Power consumption (modules)
|
For blades in the following table:
|
v Idle: blade enabled, chips initialized, no optics, ports disabled.
|
v Typical: blade enabled, optics in 50% of ports, passing line rate.
|
|
v Maximum: blade enabled, optics installed, traffic, full–line rate, 64-byte smallest packet, 40°C (104°F)
ambient temperature, maximum power for all supported optics.
|
| | | |
Module name
| | |
CPX6
|
|
@ 380 VDC
input
@ 240 or 277
VAC input
2385 W
8139 Btu/hr
2484 VA
4244 W
14485 Btu/hr
4421 VA
Module description
Control Processor Blade
Minimum number of power supplies
1 power supply for DC input (192–400
VDC)
2 for AC low line (100–120 VAC)
1 for AC high line (200–277 VAC)
1 power supply provides system power, but
2 must be installed to provide power
efficiency and redundancy.
2 power supplies for AC low line are not
supported as an HA (redundant)
configuration.
2 power supplies for DC input (192–400
VDC)
3 for AC low line (100–120 VAC)
2 for AC high line (200–277 VAC)
2 power supplies provide system power, but
4 must be installed to provide power
efficiency and redundancy
Notes
SAN256B-6 fully
loaded: 2 CP blades,
2 CR blades, 4
FC32-48 port blades,
2 fan assemblies
SAN512B-6 fully
loaded: 2 CP blades,
2 CR blades, 8
FC32-48 port blades,
3 fan assemblies
Power consumption
Idle = 38 W
Typical = 45 W
Maximum = 50 W
Appendix B. Product Specifications