Hot-Swap Replacement - IBM SAN256B-6 Installation, Service And User Manual

Storage networking
Table of Contents

Advertisement

The factory serial number and the sequence number in the following output from the chassisShow
command should match. In the ficonshow switchrnid output, a sequence number indicates the logical
switch number, if virtual fabrics is enabled:
switch:FID128:admin> chassisshow
<output truncated>
WWN Unit: 1
System AirFlow:
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
WWN Unit: 2
System AirFlow:
Header Version:
Power Consume Factor:
Factory Part Num:
Factory Serial Num:
Manufacture:
Update:
Time Alive:
Time Awake:
Chassis Factory Serial Num: AFY2530G00S
switch:admin> ficonshow switchrnid
{
{Switch WWN
10:00:00:05:1e:95:b1:00 0x00 0x200a00
Type number:
Model number:
Manufacturer:
Plant of Manufacture: CA
Sequence Number:
tag:
}
5. Contact IBM Support for replacement of WWN cards. IBM Support will request the partner or OEM
to send WWN cards from FRU inventory to the nearest IBM Support office to be reprogrammed. IBM
Support will require the Supportsave data taken in the previous step so that the replacement cards
can be reprogrammed prior to shipping to the partner or your site. If support has determined that
both WWN cards need replaced, you must replace both WWN cards as a matched pair.

Hot-swap replacement

You may replace one WWN card assembly at a time with the system powered on using the following
steps to avoid interruption of system operation.
About this task
Use this procedure if Customer Support has determined that a WWN card needs replaced and you have
received replacement cards. These procedures require that you use the wwnrecover utility. For more
information on this utility, refer to "Using the wwnrecover utility" on page 152.
You can use this procedure to replace one WWN card assembly at a time while power is on. Follow all
steps for one card, and then repeat the same steps to replace the other card assembly. To replace both
WWN card assemblies simultaneously, use procedures under "Cold-swap replacement" on page 156.
154
SAN256B-6 Installation, Service, and User Guide
Non-portside Intake
2
-1W
60-1003194-02
DZH0331L039
Day: 3 Month: 10 Year: 15
Day: 0 Month: 0 Year: 0
24 days
0 days
Non-portside Intake
2
-1W
60-1003194-02
DZH0331L032
Day: 3 Month: 10 Year: 15
Day: 0 Month: 0 Year: 0
24 days
0 days
Flag Parm
SLKWRM
SAN768B
BRD
0AFX2533G001
b6ff

Advertisement

Table of Contents
loading