3. Enter the configDownload command.
switch:admin> configdownload -all
Server Name or IP Address [host]: 123.123.123.123
User Name [None]: Admin24
File Name [config.txt]: config-switch.txt
Password: xxxxxxxx
download complete
switch:admin>
4. Reboot the device.
5. Enter the chassisEnable command to enable all user ports and enable a virtual fabric-aware chassis.

Verifying correct operation of system

About this task
Complete the following steps to verify the correct operation of the device.
Procedure
1. Log in to the device as admin.
switch:admin> login
login: admin
password: xxxxxxxx
switch:admin>
2. Enter the chassisShow command to verify that airflow direction set on WWN cards matches airflow
direction for fans in fan and power supply assemblies installed in device. Airflow direction of fans
and power supplies displays as "Fan Direction" under each fan or power supply unit. System airflow
direction displays as "System Airflow" under the WWN card unit. The following example shows
mismatch of system airflow and airflow direction in installed fan and power supply.
POWER SUPPLY Unit: 1
Power Source:
Fan Direction:
...
FAN Unit: 2
Fan Direction:
...
WWN Unit: 1
System AirFlow:
...
WWN Unit: 2
System AirFlow:
The WWN units should indicate "Non-portside Intake." If there is a mismatch of airflow direction,
RAS log messages will indicate a mismatch between system airflow direction and airflow direction of
fan in power supply or fan assembly refer to "Configuring airflow direction on WWN cards" on page
158 for instructions on configuring correct airflow direction on WWN cards.
3. Enter the slotShow -m command and verify that all the installed cards are detected and that their
status is operational (enabled).
switch:admin> slotShow -m
Slot
Blade Type
--------------------------------------------------
1
CP BLADE
2
CP BLADE
3
SW BLADE
4
SW BLADE
5
CORE BLADE
6
CORE BLADE
7
SW BLADE
8
AP BLADE
4. Verify that the device is functioning correctly by entering switchShow or switchStatusShow.
This switchShow command displays the device and port status information.
AC
Non-portside Intake
Non-portside Intake
Non-portside Exhaust
Non-portside Exhaust
ID
Model Name
Status
175
CPX6
ENABLED
175
CPX6
ENABLED
178
FC32-48
ENABLED
178
FC32-48
ENABLED
176
CR32-4
ENABLED
176
CR32-4
ENABLED
178
FC32-48
ENABLED
186
SX6
ENABLED
199
Replacing the Chassis