Details - Omron PROFINET NX-PNC202 User Manual

Machine automation controller coupler unit
Table of Contents

Advertisement

3-2-2

Details

Procedure
Preparing for
Selecting NX
Work
Units
Confirming Suit-
ability of IO
1
Device Termi-
nal Specifica-
tions
Making Hard-
Installation
ware Settings
and Wiring the
IO Device Ter-
Wiring
minal
2
Setting the PROFINET Coupler
Unit's IO Device Name
3
Configuring the IO Device Termi-
nal and Making the Operation
Settings
Creating the
Unit Configura-
tion Information
4
Setting the IO
Allocation Infor-
mation
Unit Operation
Settings
Setting Unit
Application Data
Transferring and Comparing
5
PROFINET Coupler Unit Param-
eter Settings
Setting PROFINET IO Data
6
Allocate IO Data
7
NX-series PROFINET Coupler Unit User's Manual (W623)
Item
Select the NX Units and the quantity and types of IO
that are required.
Confirm that the following specific restrictions for the IO
Device Terminal are met.
• Number of NX Units
• Design conditions for the NX Unit power supply and
IO power supply
• Installation orientation
Connect the NX Units and End Cover to the PROFINET
Coupler Unit and secure the IO Device Terminal to a
DIN Track to install it.
Wire the IO Device Terminal.
• Connect the communications cables.
• Connect the Unit power supply.
• Connect the IO power supply.
• Connect the ground wire.
• Connect the external IO devices.
Use the third party IO Controller software to set the IO
device name.
Set up the IO Device Terminal (create the configuration
and set the parameters) with the Sysmac Studio.
Create the IO Device Terminal configuration information
such as number and order of NX Units, individual NX
Unit information and information about the PROFINET
Coupler Unit.
Make the IO allocations for the PROFINET Coupler Unit
and NX Units as required.
Make the Unit operation settings for the PROFINET
Coupler Unit and NX Units as required.
Create the Unit application data. This step applies only
to Units that have Unit application data.
Transfer and compare IO Device Terminal settings with
the Sysmac Studio.
Use the third party PROFINET IO Controller software to
set the IO data.
Allocate the IO Data to the IO Controller CPU's vari-
ables.
3 Specifications and Application Procedures
Description
Reference
• 2-2-2 Types of NX
Units on page 2-6
• Manuals for the spe-
cific NX Units
• 3-1 Specifications on
page 3-2
• Section 5 Designing
the Power Supply
System
• 6-1-3 Installation Ori-
entation on page 6-8
6-1 Installing Units on
page 6-2
Section 7 Wiring
9-4 Setting PROFINET
IO Device Name on
page 9-19
9-2 Setting IO Device
Terminal Parameters on
page 9-5
9-2-2 Setting the NX
Unit Configuration Infor-
mation on page 9-5
9-6 NX Unit IO Alloca-
tion on page 9-27
9-2-3 Unit Operation
Settings on page 9-10
9-2-4 Unit Application
Data on page 9-11
9-3 Transferring and
Comparing Settings on
page 9-16
9-5 Setting PROFINET
IO Data on page 9-20
9-6 NX Unit IO Alloca-
tion on page 9-27
3 - 9
3

Advertisement

Table of Contents
loading

Table of Contents