5 Designing the Power Supply System
Installation Locations for Protective Devices
Install protective devices for the Unit power supply and IO power supply in the locations that are shown
in the following figure.
PROFINET
Coupler Unit
Unit power
supply terminals
I_unit1
Protective
device
I_io1
Protective
device
I/O power
supply
Unit power
supply
However, fewer protective devices may be required when the current consumption of each block does
not exceed the rated current. An example of this is provided below.
5 - 20
Block that is supplied I/O power from the PROFINET
Coupler Unit
Block that is supplied Unit
Block that is supplied Unit
power from the Additional
power from the PROFINET-
NX Unit Power Supply
Coupler Unit
Unit
NX Unit
NX Unit
NX Unit
Additional NX Unit
Additional NX Unit
power
power
Power Supply Unit
Power Supply Unit
supply
supply
Internal
power
supply
circuit
I/O power
I/O power
Unit power
Unit power
supply terminals
supply terminals
supply terminals
supply terminals
I_unit2
Protective
device
Block that is supplied I/O
power from the Additional
I/O Power Supply Unit
Additional I/O
Additional I/O
Power Supply Unit
Power Supply Unit
Internal
power
supply
circuit
I/O power
I/O power
supply terminals
supply terminals
I_io2
Protective
device
NX-series PROFINET Coupler Unit User's Manual (W623)
NX Unit
NX Unit
power supply
power supply