Table 7: CTP Bundle IP Parameter Settings in the CTP Menu
Field
Function
Remote
Specifies the name and IP address of the remote CTP device.
Address
Remote Circuit
Specifies the bundle to connect to on the remote CTP device.
ID
Local Circuit ID
Specifies the bundle on the local CTP device.
Packet Size
Specifies the size of IP packets that are created from data received at
the serial port.
The CTP device makes sure that the combination of packet size and data
rate does not result in a packet rate that exceeds 1200 packets per
second.
Min Buffer
Specifies the minimum average buffer size. Use a value that is greater
than the expected jitter and less than the Pkt Buffer Set parameter.
The minimum buffer ensures that the buffer does not become too small
because of timing variances between the local and remote serial
interfaces.
The entire buffer is available for accommodating and smoothing packet
delay jitter, regardless of the minimum buffer setting.
Pkt Buffer Set
Specifies the buffer size when the circuit enters a running state. This value
must be large enough to accommodate the anticipated packet delay,
and it must be set to a value greater than the minimum buffer size and
lower than the maximum buffer size.
Max Buffer
Specifies the maximum buffer size. The maximum buffer ensures that
the buffer does not become too large due to timing variances between
the local and remote serial interfaces. If the buffer size exceeds the
maximum buffer size, the buffer is recentered to the Pkt Buffer Set value.
Periodic buffer recenters are not expected. If you notice recenters, we
recommend that you verify the reference to the CTP (if used) or that you
configure one port with adaptive clocking.
28
If you select an active bundle, you are prompted to disable the bundle before
configuring it.
Select 2) Config to configure the bundle.
4.
Configure options 1 through 9 as described in
5.
Table 7 on page
28.
Your Action
Enter the address of the remote
CTP device.
Enter a number from 0 through
249.
Enter a number from 0 through
249.
For CTP150 devices, enter a
number from 8 through 1456.
For CTP2000 devices, enter a
number from 4 through 1456.
Enter a number from 0.001
through 9999.000 milliseconds.
Enter a number from 0.001
through 9999.000 milliseconds.
Enter a number from 0.001
through 9999.000 milliseconds.