Using Bundles to Create Logical Configurations for Physical Interfaces, CTP Release 7.3, CTPView Release 7.3
Table 62: Serial Loop Parameter Settings in CTPView
Field
Function
Serial
Specifies the direction of
Loop
the serial loop or removes
the serial loop.
Related
Documentation

Configuring Serial Loops for CTP Bundles (CTP Menu)

162
Your Action
Select one:
None—Removes the serial loop.
To Net—Creates a loop toward the network. Data arriving from the IP network
destined for the serial interface is looped back to the IP network and remote
customer device. The data is still transmitted from the IP network to the serial
interface, but data from the serial interface to the IP network and remote device
is blocked.
To I/F—Creates a loop toward the customer device attached to the serial interface.
Data arriving from the serial interface that is destined for the IP network is looped
back to the serial interface. The data is still transmitted from the serial interface
to the IP network, but data from the IP network to the serial interface is blocked.
Serial Loops for CTP Bundles Overview on page 157
Serial loops will run on transparent circuits only if the transparent circuits use the SD and
RD signals to transport data.
To configure serial loops with the CTP Menu:
From the CTP Main Menu, select 1) Bundle Operations.
1.
Select 1) CTP.
2.
Select a bundle from the list.
3.
Select 8) Runtime Diags.
4.
Select 1) Serial Loop.
5.
Configure the Serial Loop option as described in
6.
Table 63 on page
163.