Juniper CTP Series Manual page 32

Circuit to packet platform
Hide thumbs Also See for CTP Series:
Table of Contents

Advertisement

Using Bundles to Create Logical Configurations for Physical Interfaces, CTP Release 7.3, CTPView Release 7.3
Table 6: CTP Bundle IP Parameter Settings in CTPView
Field
Function
Bundle
Specifies identifying information about the bundle.
Description
You can use the bundle description as the search criteria when you
search for bundles from the network monitoring page.
State
Specifies whether the bundle is active or disabled.
Remote
Specifies the name and IP address of the remote CTP device.
Address
Remote Circuit
Specifies the bundle to connect to on the remote CTP device.
ID
Local Circuit ID
Specifies the bundle on the local CTP device.
Packet Size
Specifies the size of IP packets that are created from data received at
the serial port.
The CTP device makes sure that the combination of packet size and
data rate does not result in a packet rate that exceeds 1200 packets
per second.
Min Buffer
Specifies the minimum average buffer size. Use a value that is greater
than the expected jitter and less than the Buffer Set parameter.
The minimum buffer ensures that the buffer does not become too small
because of timing variances between the local and remote serial
interfaces.
The entire buffer is available for accommodating and smoothing packet
delay jitter, regardless of the minimum buffer setting.
26
Connect the CTPView server to the CTP device for which you want to configure bundles.
To configure IP parameters for CTP bundles using CTPView:
In the side pane, select Bundle > Configuration.
1.
Run your mouse over the Display and Select an Existing Bundle bar.
2.
In the table of bundles, select the bundle that you want to modify.
3.
Under Bundle Options, configure the parameters as described in
4.
and click Click to Submit Bundle AND Port Changes.
Table 6 on page 26
Your Action
Type a description for the bundle.
Select DISABLED or ACTIVE.
In the first field, select the CTP
device.
In the second field, select an
interface on the CTP device.
Enter a number from 0 through 249.
Enter a number from 0 through 249.
Select a packet size.
For CTP150 devices, the available
packet size is 8 through 1456.
For CTP2000 devices, the available
packet size is 4 through 1456.
Enter a number from 0.001 through
9999.000 milliseconds.
Copyright © 2018, Juniper Networks, Inc.