Nortel Communication Server 1000 Manual page 95

Dass2 fundamentals
Hide thumbs Also See for Communication Server 1000:
Table of Contents

Advertisement

Cable requirements
This section lists the types of cable used and the lengths required for
internal and external NT5D97AD DDP2 connections.
Note:
No additional cabling is required for nB+D configurations.
Multiple DDP2 cards and the D-channel are associated through software
in LD 17.
DDP2 cable assemblies include:
E1 carrier cables
NTCK45AA (A0407956)
NT8D7217 (A0617192)
NTCK78AA (A0618294)
NTCK79AA (A0618296)
DDP2 to QPC471/QPC775 Clock Controller Cables
NTCG03AA
NTCG03AB
NTCG03AC
NTCG03AD
DDP2 to DCH cables
NTCK46AA
NTCK46AB
NTCK46AC
NTCK46AD
A description of each type of DDP2 cable follows.
E1 carrier cables
NTCK45AA (A0407956) The NTCK45AA (8 ft.) is an 120W cable for
systems equipped with an I/O filter panel, connecting the TRK port (P1,
D-type 9 pin male) on the DDP2 faceplate to the I/O filter (P2, P3 D-type 9
pin males).
Copyright © 2007-2010 Nortel Networks. All Rights Reserved.
Nortel Communication Server 1000
DASS2 Fundamentals
NN43001-571 04.01 4 June 2010
NT5D97AD Dual-port DTI2/PRI2 card 95

Advertisement

Table of Contents
loading

Table of Contents