Table 102
DTM error messages (cont'd.)
Code
Description
DTM350
Must switch reference clock before
disabling
for DTM310, DTM311, DTM312, and
DTM316 the alarm "z" is one of the
following code numbers:
0 — TBF (Transmit Buffer Full)
1 — FAE (Frame Alignment Error)
2 — HER (High Error Rate)
3 — TSF (Transmit Signal Failure)
4 — AIS (Alarm Indicator Signal)
5 — LOI (Loss of Input)
6 — DAI (Distant Alarm Indication)
Initialize (INI) error messages
When the system is initialized, all network cards are tested for read/write
response, and all DCHIs are tested for read/write response and stuck
interrupts.
If initialization follows a system reload or is manually invoked, then all links
are brought into service (resembling a link reset). If initialization occurs for
any other reason, then the links which are not disabled are reset. All calls
that were established before initialization are rebuilt. The error messages
described in
during system initialization.
Table 103
INI messages
Code
INI003 (fault codes 90 - 12F)
INI009 (fault codes 90 - 12F)
INI100
INI101
INI1006
Table 103 "INI messages" (page 185)
Description
Network card does not respond
The network card does not respond
DCHI does not respond from active CPU
DCHI does not respond from standby CPU
Unequipped card is responding